B-65272EN/04 SPECIFICATIONS FOR THE αi SERIES 4.NOTES ON INSTALLATION
- 23 -
3) Using the motor by energizing it only with the high-speed
winding (∆ connection) rather than switching its output
•
••
• Connecting power leads to an M5
type terminal board
<1> Mounting jumpers
Mount three jumpers between the
upper and lower rows to make
electric connections between U
and Z, between V and X, and
between W and Y.
The jumpers must be mounted in
the specified orientation. See the
figure at the right.
<2> Attaching power leads
Attach the U-, V-, and W-
phase power leads to the
upper row and fasten them
with the screws.
No cover need be put on
the lower row.
V
U
W
Power lead
U
Z
Jumper
65L-0001-0630/SD
•
••
• Connecting power leads to an M6
type terminal board
<1> Mounting jumpers
Mount three jumpers to make an
electric connection in each pair of
adjacent terminals (between U
and Z, between V and X, and
between W and Y).
The jumper must be mounted in
the specified orientation. See the
figure at the right.
<2> Attaching power leads
Attach the U-, V-, and W-
phase power leads and
fasten them with the
screws.
V
W
U
Power lead
Z
U
Jumper
(A290-1410-X417)
Power leads (six)
on the motor side