B–65192EN/02
10. COMPATIBILITY WITH THE C
SERIES SERVO AMPLIFIER
99
10
COMPATIBILITY WITH THE C SERIES SERVO
AMPLIFIER
Table 10.1 Comparison between SVU/SVUC and C series Amplifier
Item
SVUC SVU
External shape and
mounting
provisions
Same as C series am-
plifier
Same as C series am-
plifier
À NC interface TYPE A interface
TYPE B interface
Type A interface
Type B interface
Á Emergency stop inter-
face
Same as C series am-
plifier (100 VAC)
24 VDC (connector
CX4)
 Surge absorber for in-
put protection
Same as C series am-
plifier
Not provided
(An external device is
required.)
à MCC monitoring con-
tact
a–contact output for
SVUC1–130 only
a–contact output for
SVU1–130 only
TUV Non–compliant Fully compliant
UL/CSA Fully compliant Fully compliant
Wiring, cable Same as C series am-
plifier
Same as C series am-
plifier, except for emer-
gency stop interface
Ä Connector positions Almost same as C se-
ries amplifier
Almost same as C se-
ries amplifier
Terminal block posi-
tions
Same as C series am-
plifier
Same as C series am-
plifier
Combination with an S
series motor
Possible Impossible
Å Power shut–off method Two–phase shut–off Two–phase shut–off
À NC interface
This unit supports both the TYPE B interface and the TYPE A
interface, only the latter being featured by the C series amplifier.
The C series amplifier uses connectors CN1(L) and CN1M for the
TYPE A interface. The corresponding connectors on the SVU/SVUC
are JV1B and JV2B.
Á ESP interface
SVU: Uses 24 VDC in the amplifier. The power connection is made
using a connector, not a terminal block.
SVUC:Uses 100 VAC, in the same way as the C series amplifier.
Model Signal Terminal Signal name
C series amplifier 1φ 100 VAC T1 (5–6) 100A – 100B
SVU 24 VDC CX4 (2–3) ESP – +24
SVUC 1φ 100 VAC T1 (5–6) 100A – 100B
10.1
COMPARISON
BETWEEN SVU/SVUC
AND C SERIES
AMPLIFIER