B–65192EN/02
3. SPECIFICATION
11
Table 3.1 (c) Specification (Each model)
L axis M axis
Axis Name Designation
Rated current
(Arms)
Current limit
(Apeak)
Rated current
(Arms)
Current limit
(Apeak)
1 SVUC1–4 A06B–6090–H002 0.9 4
SVUC1–12 A06B–6090–H003 2.9 12
SVUC1–40 A06B–6090–H004 16.0 40
SVUC1–80 A06B–6090–H006 20.0 80
SVUC1–130 A06B–6090–H008 51.0 130
2 SVUC2–4/4 A06B–6090–H222 0.9 4 0.9 4
SVUC2–4/12 A06B–6090–H223 0.9 4 2.9 12
SVUC2–4/40 A06B–6090–H224 0.9 4 8.7 40
SVUC2–12/12 A06B–6090–H233 2.9 12 2.9 12
SVUC2–12/40 A06B–6090–H234 2.9 12 8.7 40
SVUC2–12/80 A06B–6090–H236 2.9 12 10.2 80
SVUC2–40/40 A06B–6090–H244 8.7 40 8.7 40
SVUC2–40/80 A06B–6090–H246 8.7 40 10.2 80
SVUC2–80/80 A06B–6090–H266 10.2 80 10.2 80
CAUTION
1 The rated output is guaranteed under the rated input
voltage. When the input voltage fluctuates, the rated output
may not be obtained even if the fluctuation is within the
tolerance.
2 The current limit are those typical. The operating value may
vary by about "10% due to varying circuit parameters.