3. SPECIFICATION
B–65192EN/02
10
Table 3.1 (b) Specification (Each model for SVU)
L axis M axis
Axis Name Designation
Rated current
(Arms)
Current limit
(Apeak)
Rated current
(Arms)
Current limit
(Apeak)
1 SVU1–12 A06B–6089–H101 3.0 12
SVU1–20 A06B–6089–H102 5.9 20
SVU1–40 A06B–6089–H104 12.5 40
SVU1–80 A06B–6089–H105 18.7 80
SVU1–130 A06B–6089–H106 52.2 130
2 SVU2–12/12 A06B–6089–H201 3.0 12 3.0 12
SVU2–12/20 A06B–6089–H202 3.0 12 5.9 20
SVU2–20/20 A06B–6089–H203 5.9 20 5.9 20
SVU2–12/40 A06B–6089–H204 3.0 12 8.8 40
SVU2–20/40 A06B–6089–H205 5.9 20 8.8 40
SVU2–40/40 A06B–6089–H206 8.8 40 8.8 40
SVU2–40/80 A06B–6089–H207 8.8 40 10.0 80
SVU2–80/80 A06B–6089–H208 10.0 80 10.0 80
SVU2–12/80 A06B–6089–H209 3.0 12 10.0 80
SVU2–20/80 A06B–6089–H210 5.9 20 10.0 80
CAUTION
1 The rated output is guaranteed under the rated input
voltage. When the input voltage fluctuates, the rated output
may not be obtained even if the fluctuation is within the
tolerance.
2 The current limit are those typical. The operating value may
vary by about "10% due to varying circuit parameters.