10. COMPATIBILITY WITH THE C
SERIES SERVO AMPLIFIER
B–65192EN/02
102
(1) Switch setting
Some switches have been added on the front of the amplifier. The
following switches must be set:
– Interface setting (SW1)
– SVU/SVUC mode setting (SW2)
– Protection setting for regenerative discharge resistor (SW3, SW4)
Set these switches as described in Section 3.4.
(2) MCC monitoring contact output
The conventional b–contact output has been changed to the a–contact
output in the case of the SVUC1–130 only. For details, see Subsec.
9.3.15.
(3) Cable and connector
The connector names of the a series are the same as those of the NC,
but different from those of the C series amplifier. JV1B and JV2B of
the SVUC correspond to CN1(L) and CN1M of the C series amplifier.
(4) Maintenance fuse
The maintenance fuse of the C series amplifier cannot be used with
the SVUC because of a difference in ratings. As the SVUC
maintenance fuse, designate A06B–6089–K250.
D C series amplifier maintenance fuse
Control power fuse (HM32 fuse) : A06B–6066–K207
Fan motor fuse (for H008, P405H fuse) : A06B–6066–K208
D SVUC maintenance fuse (HM32 fuse)
Control power fuse (HM32 fuse) : A06B–6089–K250
Fan motor fuse (for H008, HM32 fuse) : A06B–6089–K250
(5) Connector positions
Connectors are provided for the TYPE A and TYPE B interfaces. For
details, see Section 10.1.
(6) Separate regenerative discharge resistor
A06B–6089–H*** has been modified from A06B–6066–H*** such
that it complies with VDE 0160. Their specifications (characteristics
and external dimensions) are, however, the same. A06B–6066–H***
can, therefore, be used in place of A06B–6089–H***.
NOTE
A06B–6066–H*** does not comply with VDE 0160.
10.2
NOTES ON
REPLACING A C
SERIES AMPLIFIER
WITH THE SVUC