B–65192EN/02
10. COMPATIBILITY WITH THE C
SERIES SERVO AMPLIFIER
101
Connector name
Name Interface
C series amplifier SVU/SVUC
À
NC interface con-
nector: L–axis
TYPE A CN1 (L) JV1B
Á
NC interface con-
nector: M–axis
TYPE A CN1M JV2B
Â
NC interface con-
nector: L–axis
TYPE B JS1B
Ä
NC interface con-
nector: M–axis
TYPE B JS2B
Ä
Connector for
pulse coder con-
nection: L–axis
TYPE B JF1
Å
Connector for
pulse coder con-
nection: M–axis
TYPE B JF2
NOTE
For details of the SVU/SVUC connectors, see Subsec.
9.2.3.
Å Power shut–off
The C series amplifier shuts off all three phases of the input by means
of the internal magnetic contactor. The SVU/SVUC, however, shuts
off only two phases using the internal power relay. This two–phase
shut–off enables effective shut–off of the power. If three–phase
shut–off (complete separation of the potential) is necessary, use an
externally mounted MCC.
NOTE
To gain approval to affix the CE marking (machinery
directive), an external MCC satisfying European safety
requirements is necessary. For details, see Subsec. 9.1.2.