B–65192EN/02
9. CONNECTION
69
(3) Associate ten twisted–pair wires with paires of pins 1 and 2, 3 and
4, . . . , and 19 and 20 of a connector such as PCR–E20FA when
connecting the pins with the pairs.
Specificarion
Item Unit Specificarion
Designation A66L–0001–0284#10P
Manufacturer Hitachi Cable
Oki Electric Cable
Rating 60_C 30V : UL2789
80_C 30V : UL80276
Conductor Stranded wire of tinned annealed
copper (ASIM B–286)
Material
Insulator Cross–linked vinyl
Shield braid Tinned annealed copper wire
Sheath Heat–resistant oilproof vinyl
Number of pairs pairs 10
Size AWG 28
Conductor Structure Conductors/mm 7/0.127
Outside diameter mm 0.38
Thickness mm 0.1
(Thinnest portion : 0.08)
Insulator
Outside diameter mm 0.58 (approx.)
Core style UL1571 (80_C, 30V) (rating)
Twisted
Outside diameter mm 1.16 (approx.)
pair
Pitch mm 20 or less
Lay Collect the required number of
twisted pairs into a cable, then
wrap binding tabe around the cable.
To make the cable round, apply a
cable separator as required.
Lay diameter mm 3.5 (approx.)
Drain wire Conductors/mm Hitachi : Not available
Oki : Available, 10/0.12
Shield
Element wire diameter mm 0.12
braid
Braid density % 85 or more
Color Black
Sheath Thickness mm 1.0
Outside diameter mm 6.2 (approx.)
Standard length m 200
Packing method Bundle
Electrical
Resistance Ω/km 233 or less (at 20_C)
Electrical
perfor-
Insulation resistance MΩ–km 10 or more (at 20_C)
mance
Dielectric strength V/min. 300 (AC)
Flame resistance Shall pass flame resistance tset
VW–ISC of UL standards.