C. FSSB APPENDIX B-65235EN/02
- 108 -
8. Please push the soft key[SETING].
9. Please push the function key SYSTEM .
10. [FSSB] appears after pushing several times.
11. When you push the soft key [FSSB], the screen changes
the Amplifier setting (or the screen selected before) and
the following soft key appears.
[ AMP ][ AXIS ][MAINTE][ ][ (OPRT)]
12. Please push the soft key [ AXIS ].
13. Please set the information of each axis one by one.
Please input the setting value in using the following
things.
•In using the outer detector
•In using 1 DSP/1 axis
(For example current loop 125 µs, Learning Control
etc.)
•In case of Cs axis
•In using tandem control
AMPLIFIER SETTING
No. AMP SERIES UNIT CUR. [AXIS] NAME
1 A1-L α SVM 40AL [ 1 ] X
2 A1-M α SVM 12A [ 2 ] Y
3 A2-L β SVU 20A [ 3 ] Z
4 A3-L α SVM 40A [ 4 ] A
5 A3-M α SVM 80A [ 5 ] B
7 A4-L α SVM 40AS [ 6 ] C
No. EXTRA type PCB ID
6 M1 A 0008 DETECTOR(4AXES)
8 M2 A 0008 DETECTOR(4AXES)
>
MDI **** *** *** 13:11:56
[ AMP ] [ AXIS ] [MAINTE] [ ] [ (OPRT)]