B-65235EN/02 START-UP PROCEDURE 3. START-UP PROCEDURE
- 43 -
11) Switch the NC off and on again.
This completes servo parameter initialization.If a
servo alarm related to pulse coders occurs for an
axis for which a servo motor or amplifier is not
connected, specify the following parameter.
#7 #6 #5 #4 #3 #2 #1 #0
SERD (#0) The serial feedback dummy function is:
1 : Used
0 : Not used
12) When you are going to use an α, β pulse coder as
an absolute pulse coder, use the following
procedure. The procedure for setting absolute
position communication using the α pulse coder is
somewhat different from the procedure using
serial pulse coder A.
1. Set the following parameter, and switch the
CNC off.
• Series 16,18,20,21, Power Mate-D,F,H,I
#7 #6 #5 #4 #3 #2 #1 #0
APCX (#5)
1 : Performs absolute position as communication pulse
coder.
0 : Does not perform as absolute position pulse coder.
• Series 0-C
#7 #6 #5 #4 #3 #2 #1 #0
21 APC8 AP C7 APC4 AP CZ APCY APCX
APCX to 8
1 : Performs absolute position communication for the X-,
Y-, Z-, 4-, 7-, or 8- or 8-axis.
0 : Does not perform absolute position communication for
the X-, Y-, Z-, 4-, 7-, or 8-axis.