B-65235EN/02 START-UP PROCEDURE 3. START-UP PROCEDURE
- 39 -
These read to move over so look like headings install a part
of previous.
3) Start initializing
#7 #6 #5 #4 #3 #2 #1 #0
Initial set bits 1 1 DGPR 0
(#3 is set automatically to 1 except for Series 0)
4) Specify the motor Type No. Select the motor Type
No. according to the model and specification (four
digits in the middle segment of A06B-XXXX-
BXXX) of your motor.
Motor model αC3/2000 αC6/2000 αC12/2000
Motor specification 0121 0126 0141
Motor type No. 7 8 9
Motor model α1/3000 α2/2000 α2/3000
Motor specification 0371 0372 0373
Motor type No. 61 46 62
Motor model β0.5/3000 β1/3000 β2/3000
Motor specification 0113 0031 0032
Motor type No. 13 35 36
Motor model β3/3000 β6/2000
Motor specification 0033 0034
Motor type No. 33 34
5) Set AMR as described below. The setting does
not depend on the model of the motor.
α pulse coder 00000000
β pulse coder 00000000
#4: Bit to enable extending the position gain range (should be set to 1)
#3: 0 (Series)
1 (other than Series 0-C) (automatically set to 1)
(Keep the CNC power on until step 11.)
This bit is set to 1 automatically
after initializing
PLC0 (#0) = 0
DGPR (#1) = 0
Start initializing