B-65322EN/02 SVM 9.TOTAL CONNECTION DIAGRAM
- 85 -
9.2.7 Details of Cables K4 and K5
9.2.7.1 SVM1-4i and SVM1-20i
When a regenerative discharge resistor is used
The following regenerative discharge resistor models are available.
A06B-6130-H401
The following housing and contact are
connected to the resistor.
A06B-6130-H402
The following housing and contact are
connected to the resistor.
βi SVM
Regenerative
discharge resistor
DCP
DCC
TH1
TH2
CXA20
CZ7
DCP
DCC
B1
1
1
2
i SVM
D-3000 series
Housing : 175362-3
Contact : 1-175218-2
Manufacture : Tyco Electronics AMP
Wire cross-sectional area :
0.50 to 1.25mm
2
D-2000 series
Housing : 1-1318120-3
Contact : 1318107-1
Manufacture : Tyco Electronics AMP
Wire cross-sectional area :
0.30 to 0.85mm
2
For connection tools, see Subsection 9.2.3.