B-65322EN/02 SVPM 9.TOTAL CONNECTION DIAGRAM
- 141 -
9.2 CONNECTOR LOCATION
No. Name Remarks
1 STATUS1 Status LED : spindle
2 STATUS2 Status LED : servo
3 CX3 Main power MCC control signal
4 CX4 Emergency stop signal (ESP)
5 CXA2C 24VDC power input
6 COP10B Servo FSSB I/F
7 CX5X Absolute Pulsecoder battery
8 JF1 Pulsecoder : L axis
9 JF2 Pulsecoder : M axis
10 JF3 Pulsecoder : N axis
11 JX6 Power outage backup module
12 JY1
Load meter, speedometer, analog
override
13 JA7B Spindle interface input
14 JA7A Spindle interface output
15 JYA2
Spindle sensor M
i, MZi
16 JYA3
α position coder
External one-rotaion signal
17 JYA4 (Unused)
18 TB3 DC link terminal block
19
DC link charge LED
(Warning)
20 TB1
Main power supply cnnection terminal
board
21 CZ2L Servo motor power line : L axis
22 CZ2M Servo motor power line : M axis
23 CZ2N Servo motor power line : N axis
24 TB2 Spindle motor power line
25
Tapped hole for grounding the flange
WARNING
Do not touch any component in the
module or any connected cable when
LED 19 is on, because it is dangerous.
1819 20
21
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
22
24
23
25