B-65322EN/02 SVPM 9.TOTAL CONNECTION DIAGRAM
- 157 -
Connector pin assignment
JA7A and JA7B
9 5V
(Note 1)
7
5
3 SOUT
1 SIN
10
8
6
4 *SOUT
2 *SIN
19
17
15
13
11
20 5V
(Note 1)
18 5V
(Note 1)
16 0V
14 0V
12 0V
NOTE
1 The +5V pin is intended for optical link transmission
based on the optical I/O link adapter. Do not use it
when a metal cable is being used; otherwise, the
+5V line of the CNC will be short-circuited with that
of the SVPM.
2 SVPM serial interface connection using an optical
fiber cable
The use of an optical I/O link adapter with the SVPM
serial interface extends the maximum allowable
length of the optical fiber cable to up to 200 m.
Use optical fiber cables in the following cases:
• When the required cable length is 20 m or longer.
• When the cable must be extended across multiple
cabinets, and the cabinets cannot be connected
with a grounding wire 5.5 mm
2
or larger.
• The cable may be affected by noise, for example,
if the cable is laid near a strong magnetic noise
source like a welding machine or in parallel with a
power line over a long distance.