B-65322EN/02 I/O Link 9.TOTAL CONNECTION DIAGRAM
- 231 -
9.2.16.2 Connection when FANUC's manual pulse generator is used
Details of cable K23
Cable K23 is a signal cable used to connect the manual pulse
generator and adapter (JA54).
Connector: FI40-2015S
Case: FI-20-CV
(M3 screw terminal)
+5V 0V A B
+5V 0V HA1 HB1
Manual pulse generator
Manual pulse generator adapter
K23
Cable connection (K23)
HA1
HB1
+5V
0V
B
+5V
0V
HA1
HB1
+5V
0V
Shield
JA54
(PCR-EV20MDT)
1
HA1 11
2 HB1 12
0V
3
(HA2)
13
4
(
HB2
)
14
0
V
5 15
6
16
0V
7 17
8 18 +5V
9 +5V 19
10
20 +5V
Manual pulse generator
1
2
9,18,20
12,14,16
JA54
#24AWG
#20AWG
Recommended cable:
A66L-0001-0286 (#20AWG × 6 + #24AWG × 3 pairs)
Recommended connector (JA54 side)
Connector: FI40-2015S (Hirose Electric Co., Ltd.)
Case: FI-20-CV (Hirose Electric Co., Ltd.)
Recommended cable:
A02B-0259-K821 (7m) Change the connector name before use.
Although the maximum cable length is 50 m, the length is further
limited because of the power supply voltage drop as follows:
Limitation due to power supply voltage drop
Suppress the power supply voltage drop due to the cable resistance to
0.2 V or less (the sum of the voltage drop of both the 0V and 5V lines).
Perform calculation assuming that the power supply current of the
manual pulse generator is 0.1 A.
In the calculations, the cable length must include the cable length of
K24.