9.TOTAL CONNECTION DIAGRAM SVM B-65322EN/02
- 68 -
9.1.2 SVM1-40i and SVM1-80i
NC
C
line
filter
Stabilized
power supply
24 VDC
Battery
case
K7
K8
Separated
regenerative
discharge resistor
3-phase : 200 to 240VAC
5 A
Circuit
breaker
Optical cable
Optical
cable
K6
24 V power
supply for
motor brake
CZ4
CX29
CX30
CXA20
CXA19B CXA19A
COP10B COP10A
JX5
FUSE
CX5X
i
SVM
80A
JF1
Lightning
surge
absorber
40-A type, 80-A type
CZ4
CX29
CX30
CXA20
CXA19B CXA19A
COP10B COP10A
JX5
FUSE
CX5X
β
i
SVM
40A
JF1
CZ5
CZ6
CZ5
CZ6
K5
K4
K3 K3 K1 K1
K2 K2
K11
K5
K4
K9
Fan unit
Emergency
stop switch
K10
K10
CAUTION
1 Always install the circuit breakers, magnetic contactor, and
AC line filter.
2 Use the stabilized 24VDC power supply for the amplifier.
24VDC power supply for the amplifier and 24VDC power
supply for the motor brake cannot be shared.
3 The cabling of CX29 and CX30 of the second and
subsequent amplifiers may be omitted. For details, see
"TOTAL CONNECTION DIAGRAM".
4 Leave JX5 open.
Circuit
breaker
Magnetic
contactor
NOTE
1 Always install the circuit breakers, magnetic
contactor, and AC line filter.
2 To protect the equipment from lightning surge
voltages, install a lightning surge absorber across
each pair of power lines and across each power line
and the grounding line at the power inlet of the
power magnetics cabinet.