9.TOTAL CONNECTION DIAGRAM SVM B-65322EN/02
- 90 -
9.2.9 Details of Cable K7
β
i
SVM
CX29
Internal
contact
Coil
Spark killer
External power supply
(Use an appropriate power supply for the coil voltage
the customer uses.)
MCC
1
3
D-2000 series
Housing : 3-1318130-3
Contact : 1318107-1
pplicable wire: 0.3 to 0.85 mm
2
Manufacture : Tyco Electronics AMP
For connection tools, see Subsection 9.2.3.
Internal contact capacity
Resistance load
(COS
φ=1)
Inductive load
(COS φ=0.4, L/R=15msec)
Rated load 250VAC, 3A / 24VDC, 5A 250VAC, 2A / 24VDC, 1A
Maximum
contact
capacity
5A 5A
NOTE
1 To protect the internal contact, be sure to insert a
spark killer (CR) that matches the magnetic
contactor used.
2 When more than one servo amplifier is connected,
the cabling of the second and subsequent
amplifiers may be omitted.