B-65322EN/02 APPENDIX A.CONNECTING THE REACTOR AND LINE FILETER
- 245 -
A.2 CONNECTION EXAMPLES
Correct connection
Power supply regenerative
amplifier (Note 1)
Resistance regenerative
amplifier (Note 2)
Resistance regenerative
amplifier (Note 2)
Power supply regenerative
amplifier (Note 1)
One power supply regenerative amplifier is
connected to one rector.
•
The line filter is connected from the primary
side of the rector.
•
More than one resistance regenerative
amplifier can be connected to the line filter.
(The current rating of the line filter must not
be exceeded, however.)
Line filter
(Note 4)
Reactor (Note 3)
Reactor (Note 3)
Incorrect connection (1)
Resistance regenerative
amplifier (Note 2)
Resistance regenerative
amplifier (Note 2)
Reactor
(Note 3)
Power supply regenerative
amplifier (Note 1)
The resistance regenerative amplifier is
connected to the secondary side of the
rector.
The resistance regenerative amplifier may be
damaged.
The power supply regenerative amplifier may
malfunction.
Incorrect connection (2)
Resistance regenerative
amplifier (Note 2)
Resistance regenerative
amplifier (Note 2)
Reactor
(Note 3)
Power supply regenerative
amplifier (Note 1)
The line filter is connected from the
secondary side of the rector.
The resistance regenerative amplifier may be
damaged.
The power supply regenerative amplifier may
malfunction.
Line filter
(Note 4)
Incorrect connection (3)
Power supply regenerative
amplifier (Note 1)
Reactor
(Note 3)
Power supply regenerative
amplifier (Note 1)
More than one power supply regenerative
amplifier is connected to one reactor.
One power supply regenerative amplifier may
be damaged.
The other power supply regenerative amplifier
may malfunction.
NOTE
Any devices must not be connected between the
rector and power supply regenerative amplifier.
Otherwise, the connected device may be damaged
and the power supply regenerative amplifier may
malfunction.