6.INSTALLATION CONDITIONS AND NOTES SVM B-65322EN/02
- 40 -
(2) Surge absorber for single-phase input
When using an integrated lightning surge absorber between the
power lines and between each power line and a ground
(a)
(b)
Main circuit
power
input
Control power
input
200VAC
β
i
SVM
Stabilized
power
supply
(24 VDC)
To other units
Lightning surge absorber between powe
lines and between each line and ground
(R.C.M-601BUZ-4)
Circuit
breaker 1
Magnetic
contactor
C line filter
Circuit breaker 2
(5A)
Ground-fault circuit interrupte
for power magnetics cabinet
Ground plate
G
R
S
T
When using separate lightning surge absorbers between the power
lines and between each power line and a ground
R
(a)
(b)
Main circuit
power
input
200VAC
Control power
input
β
iSVM
Stabilized
power
supply
(24 VDC)
To other units
Lightning surge absorber between
power lines (R.A.V-781BYZ-2)
Circuit
breaker 1
Magnetic
contactor
C line filte
Circuit breaker 2
(5A)
Ground-fault circuit interrupte
for power magnetics cabinet
Ground plate
G
S
T
Lightning surge absorber between
each power line and ground
(R.A.V-781BXZ-4)
β
i SVM