3.SPECIFICATIONS SVPM B-65322EN/02
- 108 -
3.5 CIRCUIT BREAKER, MAGNETIC CONTACTOR, AND AC
REACTOR
3.5.1 AC Line Filter and Magnetic Contactor
The ratings of the circuit breakers and magnetic contactor are
determined by the specifications of the power supply module used.
The ordering specification drawing numbers and specifications of
circuit breakers and magnetic contactors are listed below.
When the user prepares circuit breakers and a magnetic contactor, use
those that satisfy the specifications listed below.
- Specifications of circuit breakers and magnetic contactors
SVPM name Circuit breaker 1 Circuit breaker 2 Magnetic
contactor
SVPM*-5.5i
(*: 2 or 3)
30A 30A
SVPM*-11i
(*: 2 or 3)
55A 55A
SVPM*-15i
(*: 2 or 3)
70A
5A
70A
NOTE
1 For the locations of the circuit breakers and
magnetic contactor, see Section 1.2,
"CONFIGURATION".
2 Select the rated voltages of the circuit breakers
according to the power supply voltage.
- Recommended products
Manufactured by Fuji Electric Co., Ltd.
SVPM name Circuit breaker 1 Circuit breaker 2 Magnetic
contactor
SVPM*-5.5i
(*: 2 or 3)
EA103B/50 SC- N 1
SVPM*-11i
(*: 2 or 3)
EA103B/60 SC- N 2
SVPM*-15i
(*: 2 or 3)
EA103B/75
EA33/5
SC- N2S
NOTE
For details, refer to the brochure supplied by Fuji
Electric Co., Ltd.
Note that the coil voltage specification of the
magnetic contactor varies depending on the power
supply voltage and frequency used.