B-65322EN/02 SVM 3.SPECIFICATIONS
- 19 -
Cautions for selecting a regenerative discharge resistor
WARNING
1 Regenerative discharge resistors may become
very hot (100 to 200 °C). Be careful not to touch
them.
2 Before touching a regenerative discharge resistor,
for example, for maintenance purposes, turn off all
power to the amplifier, wait for at least 30 minutes,
and make sure that the DC link charge indicator
LED (CAUTION CHARGE) is off and the
regenerative resistor is sufficiently cold.
3 When mounting a regenerative resistor, keep it
sufficiently far from any flammable.
(1) Related ordering numbers
Capacity
Wind speed
Ordering number of
regenerative
discharge resistor
Resistance
0 m/s 2 m/s 4 m/s
Remarks
A06B-6130-H401 30 Ω 20 W - - For 4/20 A
A06B-6130-H402 30 Ω 100 W - - For 4/20 A
A06B-6089-H500 16 Ω 200 W 400 W 600 W For 40/80 A
A06B-6089-H713 16 Ω Incorporates a cooling fan motor. 800 W For 40/80 A
A06B-6089-H714 16 Ω Incorporates a cooling fan motor. 1200 W For 40/80 A
(2) Mounting requirements
(a) Cautions in mounting
A06B-6130-H401
A06B-6130-H402
Install these models in a completely sealed cabinet.
A06B-6089-H500
A06B-6089-H713
A06B-6089-H714
Place the pin side and resistor side (heat generating section) of these models, respectively, in
a completely sealed cabinet and an exhaust air duct.
(a) Use accompanying gaskets.
(b) Make arrangements so that the pin side and resistor side (heat generating section) can
be kept from coolant, oil mist, and cuttings.
(c) When taking in fresh air to the resistor (heat generating section), use an air filter at the air
inlet. Also seal the cable inlets, cable outlets and doors securely.
(b) Ambient temperature
0 to 55 °C (at operation)
-20 to 60 °C (at keeping and transportation)
(c) Humidity
Normally 90 % RH or below, and condensation-free
(d) Vibration
In operation : Below 0.5 G
(e) Mounting direction:
Mount the unit securely while referring to the mounting
diagram given below.