B-65322EN/02 SVPM 9.TOTAL CONNECTION DIAGRAM
- 151 -
NOTE
1 The ground plate to which the shield is connected
must be placed as close as possible to the servo
amplifier so that distance between the ground plate
and the servo amplifier becomes shortest.
2 In case that the cable is prepared by MTB, total
resistance of 5V and 0V must be less than 2Ω.
3 Pulsecoder side connector can accept maximum
0.5mm
2
(wire construction 20/0.18 or 104/0.08,
diameter φ1.5 or less) wire and sheath diameter is
φ5.7 to φ8.0. In case of using thicker wire or cable,
take measures described below.
The total resistance (Round
trip) of 5 V and 0 V must be
less than 2
Ω
.
[Case 1] Cable conductor exceeds 0.5mm
2
. [Case 2] Sheath diameter of exceeds
8.
Soldering or crimping
Servo motor
SVM
Connector
Cable thicker than
φ
8
SVM
Servo motor
The total resistance (Round
trip) of 5 V and 0 V must be
less than 2
Ω
.
4 In case of incremental Pulsecoder, 6V is not
necessary to be connected.
• Crimp tool specification
A06B-6114-K201/JN1S : For 0.3 mm
2
A06B-6114-K201/JN1L : For 0.18 mm
2
or 0.5 mm
2
• Connector kit specification
A06B-6114-K204/S : Straight plug (including a contact)
A06B-6114-K204/E : Elbow plug (including a contact)
• Recommended cable
A66L-0001-0460 : Flexible cable 28m or less long
A66L-0001-0462 : Flexible cable 50m or less long
A66L-0001-0481 : Fixed cable 28m or less long
A66L-0001-0491 : Fixed cable 50m or less long