4. DESCRIPTION OF PARAMETERS
B–63200EN/03
14
#7
PS815025
#6
PS7
#5
PS6
#4
PS5
#3
PS4
#2
PS3
#1
PS2
#0
PS1
PS1615026 PS15 PS14 PS13 PS12 PS11 PS10 PS9
[Data type] Bit
PS1 to PS16 Discharge tube selection when half of the discharge tubes are used
Four of eight discharge tubes can be selected. Set the bit corresponding to
the discharge tube to be used to 1. Set the other bits to 0.
NOTE
Parameter No.15026 is provided for extension of the
discharge tubes. This parameter is not used at present. Set
all bits to 0.
#7
PS815027
#6
PS7
#5
PS6
#4
PS5
#3
PS4
#2
PS3
#1
PS2
#0
PS1
PS1615028 PS15 PS14 PS13 PS12 PS11 PS10 PS9
[Data type] Bit
PS1 to PS16 Discharge tube selection when all of the discharge tubes are used
All of the eight discharge tubes can be selected. Set the bit corresponding
to the discharge tube to be used to 1. Set the other bits to 0.
NOTE
Parameter No.15028 is provided for extension of the
discharge tubes. This parameter is not used at present. Set
all bits to 0.
4.2
DISCHARGE TUBE
SELECTION