4. DESCRIPTION OF PARAMETERS
B–63200EN/03
34
15245 In–tube pressure control gain 2
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
Specify a gas pressure control gain for reference discharge. This setting is
valid when bit 1 (LGC) of parameter No. 15000 is set to 1.
15246 Pressure control integral gain
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
The setting is the feedback gain of an integral element for gas pressure
control.
15247 Pressure control integral element preset value
[Data type] Word
[Unit of data]
[Valid data range] –32768 to 32767
The setting is the preset value of an integral element for gas pressure
control.
15248 Lowest permissible gas pressure
[Data type] Word
[Unit of data] (1=13 Pa)
[Valid data range] 0 to 32767
When the gas pressure is low but reaches this setting, no alarm is raised.
15249 Gas pressure rise time
[Data type] Word
[Unit of data] Second
[Valid data range] 0 to 32767
Specify a gas pressure rise time in sequence 27.