5. DESCRIPTION OF PARAMETERS
(YP SERIES)
B–63200EN/03
85
15208 Number of steps for power calibration
[Data type] Byte
[Unit of data] 0.1 msec
[Valid data range] 0 to 20
Set the number of steps for power calibration.
15209 Frequency for power calibration
[Data type] Word
[Unit of data] Hz
[Valid data range] 0 to 200
Set the frequency for power calibration.
15215 Power input calibration coefficient
[Data type] Word
[Unit of data]
[Valid data range] 102 (0.1 210) to 10240 (10 2
10
) (When 0 is specified, 1024 (1 2
10
)
is assumed.)
[Standard setting] Refer to the attached power sheet.
Specify a power input calibration coefficient.
15216 Time constant of power display filter
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
[Standard setting] 60
Specify a time constant for the filter that suppresses flickering of the
power display.
15218 Maximum current value
[Data type] Word
[Unit of data] A
[Valid data range] 0 to 1000
If the specified current value is greater than this value, an alarm is
generated.