B–63200EN/03
4. DESCRIPTION OF PARAMETERS
65
15650 Z–axis retraction amount
[Data type] Two–word
[Unit of data]
Increment system Unit IS–A IS–B IS–C
Metric input mm 0.01 0.001 0.0001
Inch input inch 0.001 0.0001 0.00001
[Valid data range] 1 to 99999999
Specify the amount of Z–axis retraction if it occurs before inverted
movement or skip starts.
15651 Amount of inverted movement
[Data type] Word
[Unit of data]
Increment system Unit IS–A IS–B IS–C
Metric input mm 10 1 0.1
Inch input inch 1 0.1 0.01
[Valid data range] 1 to 8000
Specify the amount of inverted movement, which is the distance between
the start and end points of the inverted movement.
15652 Resumption completion distance
[Data type] Word
[Unit of data]
Increment system Unit IS–A IS–B IS–C
Metric input mm 10 1 0.1
Inch input inch 1 0.1 0.01
[Valid data range] 1 to 8000
The system assumes that the inverted movement processing ends when
the amount of travel since a program is resumed after the resumed
non–inverted movement up to the start point of the inverted movement
ends exceeds this setting.
15653 Retry count
[Data type] Word
[Unit of data] Count
[Valid data range] 0 to 100
When a program is resumed after the resumed non–inverted movement up to
the start point of the inverted movement ends, an attempt is made to repeat
the inverted movement processing if inverted movement signal RVS (bit 0 of
G007) is accepted before the resumption completion distance set with
parameter No.15652 is reached. The number of times the processing is
repeated is counted. If the number of times exceeds this setting, the inverted
movement processing is stopped and skip to the next block is performed.
4.28
SETTINGS RELATED
TO MACHINING
RESUMPTION