B–63200EN/03
4. DESCRIPTION OF PARAMETERS
23
15100 Assist gas selection
[Data type] Word
[Unit of data]
[Valid data range] 0 to 7 (when bit 0 of parameter No. 15001 is set to 1)
0 to 3 (when bit 0 of parameter No. 15001 is set to 0)
Specify an assist gas type.
15101 Flow pattern selection
[Data type] Word
[Unit of data]
[Valid data range] 1 to 3
Specify an assist gas flow pattern.
15102 Pre–flow time 1
15103 Pre–flow time 2
15104 Pre–flow time 3
[Data type] Word
[Unit of data] 10 milliseconds
[Valid data range] 0 to 32767
Specify the pre–flow time of the assist gas.
15108 After–flow time 1
15109 After–flow time 2
15110 After–flow time 3
[Data type] Word
[Unit of data] 10 milliseconds
[Valid data range] 0 to 32767
Specify the after–flow time of the assist gas.
4.7
SETTINGS RELATED
TO ASSIST GAS
PRESSURE AND
TIME