5. DESCRIPTION OF PARAMETERS
(YP SERIES)
B–63200EN/03
86
15219 Minimum current value
[Data type] Word
[Unit of data] A
[Valid data range] 0 to 1000
If the specified current value is less than this value, an alarm is generated.
15220 Minimum waveform magnification
[Data type] Word
[Unit of data] %
[Valid data range] 1 to 100
If the waveform magnification is less than this value, it is clamped to this
value.
15221 Maximum frequency
[Data type] Word
[Unit of data] Hz
[Valid data range] 1 to 400
If the frequency is greater than this value, it is clamped to this value.
15256 Off interlock cancellation wait time
[Data type] Word
[Unit of data] sec
[Valid data range] 0 to 32767
Set the off interlock cancellation wait time during RUN–OFF.
15266 Output limit
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
[Standard setting] 1500
When the actual power exceeds this value, an alarm is raised.