4. DESCRIPTION OF PARAMETERS
B–63200EN/03
54
15554 Constant for clamping Z–axis tracing speed
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
The setting is used as the constant for clamping the tracing speed. Specify
the value obtained using the following expression:
Tracing speed clamp constant +
P 4
Le
P : Number of pulses detected by the pulse coder per motor revolution
(P/rev) (2048 for the serial A or α motor)
Le : Amount of machine movement per motor revolution (mm/rev)
15555 Upper limit on feedrate for the withdrawing side
[Data type] Word
[Unit of data] mm/min
[Valid data range] 0 to 32767
[Standard setting] 1200
Specify an upper limit on the feedrate for the withdrawing side.
15556 Constant for clamping W–axis tracing speed
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
This setting is used as the constant for clamping the tracing speed. Specify
the value obtained using the following expression:
Tracing speed clamp constant +
P 4
Le
P : Number of pulses detected by the pulse coder per motor revolution
(P/rev) (2048 for the serial A or α motor)
Le : Amount of machine movement per motor revolution (mm/rev)