8.EDITING PROGRAMS OPERATION B-63784EN-1/01
- 234 -
Stopping registration
While a program is being loaded, pressing the [STOP] soft key causes
loading of the program to stop. Once stopped, loading cannot be
resumed.
Explanation
- Program end codes in files and program numbers
Usually, M02, M30, and M99 are program end M codes. The available
program end codes differ depending on the settings of parameter NPE
(bit 3 of No. 2200) and NM9 (bit 4 of No. 2200), as shown below.
Depending on the available program end codes, the program numbers
differ, as does the way in which programs are separated.
Table 8.1.1 Program End M Codes
Parameter NPE=0, NM9=0 NPE=0, NM9=1 NPE=0, NM9=0 or 1
Program end M code M02, M30, M99 M02, M30 None
Program number O number or the sequence number
of the start block
O number only
Single program
- Program number to program end
- Program number to program end Program number to
the block immediately preceding the O number
O number to the block immediately
preceding the O number
- Registerable programs
Programs from O00000001 to 99999999 can be registered. How
programs are to be handled is determined with the following
parameters:
Parameter RDL (bit 0 of No. 2200)
When all programs are to be registered in the foreground at the same
time
0: The programs are added after the previously registered programs
1: The programs are registered after the previously registered
programs are deleted.
Parameter REP (bit 1 of No. 2200)
Programs with the same program numbers as those registered
previously:
0: Cannot be registered.
1: Registered after those registered previously are deleted.
Parameter NE8 (bit 0 of No. 0011)
Programs with numbers 8000 to 8999:
0: Can be edited (can be registered).
1: Cannot be edited (cannot be registered).
Parameter NE9 (bit 0 of No. 2201)
Programs with numbers 9000 to 9999:
0: Can be edited (can be registered).