10.DISPLAY OPERATION B-63784EN-1/01
- 500 -
On a single main screen, a single sub screen can be displayed.
Different sub screens can be displayed on different main screens.
(Switching the main screen causes the sub screen to be switched also.)
Once a sub screen is displayed, information about the sub screen
(displayed data, display position, and size) is stored, eliminating the
need to set up the sub screen each time the power is turned on.
NOTE
1 A help screen and a sub screen cannot be displayed
at the same time.
When a help screen is displayed, displaying a sub
screen causes the help screen to disappear. Erasing
the sub screen causes the help screen to reappear.
When a sub screen is displayed, displaying a help
screen causes the sub screen to disappear. Erasing
the help screen causes the sub screen to reappear.
2 This function cannot be used when a character card is
inserted.
3 Sub screens cannot be displayed on screens created
with the macro executor, PMC screens, and screens
created in C.
Display items
On a sub screen, the following items can be displayed:
- Actual position
- Contents of the program
- Tool offset
- Work zero offset
- Custom macro variable
- Modal information
- DI signal
- DO signal
- Servo positional deviation
- Alarm message
- Operator message