B-63784EN-1/01 OPERATION 10.DISPLAY
- 489 -
Setting input/output data
1) Press the [DATA SELECT] soft key.
The items of data that can be input/output are displayed on the soft
keys. If the desired item is not displayed, press the [NEXT
DATA] soft key to update the soft key display.
2) Press the soft key corresponding to the item to be input/output.
Soft key, indicating An
item of input/output data
Data type
Program NC program
Parameter System parameter
Pitch error Pitch error compensation data
Tool compensation Tool offset data
Work offset Workpiece origin offset data
Macro variable Custom macro variable
System log System log data
PERIODMAINTE1 Periodic maintenance data
PERIODMAINTE2 Item selection menu (machine system) data
Volumetric error Volumetric compensation data
Number offset Tool offset data with a tool number
Fixture offset Fixture offset data
Dynamic compensation Rotary head dynamic tool compensation data
System configuration System configuration data
Operation history Operation and alarm history data
Setting the output file name
Entering the file name with the MDI keys
1) Press the [NAME INPUT] soft key.
File Name> is displayed in the key-in buffer.
2) Press the [“FILE NAME] soft key.
" is added to the key-in buffer.
3) Enter the file name with the MDI keys.
4) Press the [FILE NAME”] soft key.
" is added after the file name.
5) Press the [EXEC] soft key.
The output file name is set.
Selecting a file from a file list
1) Display a file list.
See "Displaying a file list," described earlier.
2) Position the cursor to the desired output file name.
3) Press the [NAME GET] soft key.
The output file name is set.