B-63784EN-1/01 OPERATION 10.DISPLAY
- 527 -
2 About 34.9
minutes
About 69.9
minutes
About 139.8
minutes
3 or 4 About 17.4
minutes
About 34.9
minutes
About 69.9
minutes
NOTE
1 The disturbance load torque data is represented as a
percentage of the rated torque.
2 If the sample data preservation function is enabled
(parameter SPL (bit 2 of parameter number 4660) =
1), the time during which the torque data can be
stored becomes half.
3 If the value in the above table is exceeded, no more
data will be stored, even if the torque sensing
command signal is 1.
4 The stored torque data is erased when the power is
switched off. If you want to keep the torque data after
the power is switched off, save it as sample data or
save it to a memory card.
5 When the torque sensing command signal is reset to
0, the CNC suspends storing the torque data. When
the signal is set to 1 again, the CNC restarts to store
the torque data from a point of break. To start storing
from scratch, input the store counter clear signal.
6 Even when an attempt is made to store the servo
motor torque data and the spindle motor torque data
at the same time, they are not for the same time. This
is because the servo motor data may delay by up to 9
ms.