9.SETTING AND DISPLAYING DATA OPERATION B-63784EN-1/01
- 314 -
Setting of setting parameters
- Mode setting
Select MDI mode, or enter the emergency stop state by pressing the
emergency stop button.
- Data protection key
Turn on the data protection key (KEY2).
- Positioning the cursor
Position the cursor to the setting parameter you want to set.
Method 1
Using the page keys and the cursor keys
, position the cursor.
Method 2
(1) Press the [NUMBER SEARCH] soft key.
(2) Key in a setting parameter number.
(3) Press the [EXEC] soft key.
Method 3
(1) Key in a setting parameter number.
(2) Press the [NUMBER SEARCH] soft key.
- Entering settings (absolute input)
Method 1
(1) Press the [INPUT] soft key.
(2) Enter a number you want to set.
(3) Press the [EXEC] soft key.
Method 2
(1) Enter a number you want to set.
(2) Press the [INPUT] soft key.
Method 3
(1) Enter a number you want to set.
(2) Press the key.
- Entering settings (incremental input)
Method 1
(1) Press the [+INPUT] soft key.
(2) Key in an incremental or decremental value relative to the
current setting.
(3) Press the [EXEC] soft key.
PAGE
PAGE
INPUT