3.MANUAL OPERATION OPERATION B-63784EN-1/01
- 66 -
The above is an example. Refer to the appropriate manual provided by
the machine tool builder for the actual operations.
Limitations
- Acceleration/deceleration for rapid traverse
Feedrate, time constant and method of automatic acceleration/
deceleration for manual rapid traverse are the same as G00 in
programmed command.
- Change of modes
Changing the mode to the jog mode while pressing a feed axis and
direction selection switch does not enable jog feed. To enable jog
feed, enter the jog mode first, then press a feed axis and direction
selection switch.
- Rapid traverse before reference position return
When the stored stroke limit option is supported, if reference
position return is not performed after the power is turned ON,
pressing the RAPID TRAVERSE button does not actuate rapid
traverse on the axis to which the reference position return function
is programmed; the feedrate remains at the jog feedrate. As the
stored stroke limit is effective until reference position return is
performed, axis movement at the rapid traverse rate up to the
stroke end is prevented. This function can be disabled by setting
bit 2 (RPD) of parameter No.1400.
0 2000
JOG FEED RATE OVERRIDE
50 100
25
F0
RAPID TRAVERSE
OVERRIDE (%)