B-63784EN-1/01 OPERATION 2.OPERATIONAL DEVICES
- 57 -
Parameter
Before an external input/output device can be used, parameters must be
set as follows.
Each external input/output device is temporarily assigned a device
number from 1 to 6. When four external input/output devices are used,
for example, a device number from 1 to 4 is assigned to each device.
After the device numbers are assigned to the external input/output
devices, their specifications are set in parameter Nos. 5110 to 5162.
The numbers of the external input/output devices attached to channels
1, 2, 3, and 13 are set in parameter Nos. 5001, 5002, 5003, and 5013.
MAIN CPU BOARD
DISPLAY UNIT
Channel 1
Channel 2
Channel 3
JD5A
JD5B
RS-422RS-232-CRS-232-C
JD36A
JD6A
RS-232-C
Reader
puncher
Host
computer
Host
computer
Reader
puncher
I/O CHANNEL=1 I/O CHANNEL=2
I/O CHANNEL=3 I/O CHANNEL=13
CNC
Channel 13
Parameter number
Foreground
Background
Channels used by
input/output
devices
0020
0021
0022
0023
5001
1
5002
2
5003
3
5013
13
Device number
used for each
channel
Channel No.
Device No.
3 :
4 :
5 :
5111
1
5110
5112
Device specification
Number of stop bits
Baud rate
5121
2
5120
5122
Device specification
Number of stop bits
Baud rate
5161
6
5160
5162
Device specification
Number of stop bits
Baud rate