B-70265EN/02 7.UNITS
- 139 -
Fig.7.4.1(e) Identification numbers (C6000-E)
7.4.2 Replacement Method
(1) Turn off the power to the CNC, then turn off the power to the
laser oscillator.
(2) Remove the top cover of the oscillator.
(3) Detach the cable and feeder connecting the discharge tube with
the matching box, by loosening the thumbscrew.
Remove all the screws from the flange which secures the
discharge tube.
(4) Move the discharge tube toward the output, rear, and folding
mirrors, while rotating it. If the O-ring is too tight to allow the
discharge tube to be moved, lubricate the O-ring with alcohol.
Before attempting to move the discharge tube, however, move
the flange to the center of the tube. Then, hold the supported end
of the discharge tube, leaving a gap of 5 mm, then push the
discharge tube while rotating it. At this time, be careful not to
damage the end of the discharge tube.
(5) Move the O-ring to the center of the discharge tube, then remove
the discharge tube. If the O-ring is at the end of the discharge
tube, the end of discharge tube may be damaged while it is being
removed.
(6) Remove the copper plate (or feeder) from the removed discharge
tube, then mount it on a new discharge tube.
(7) Mount the flange onto the new discharge tube, then mount a new
O-ring. Before mounting the O-ring, wipe it with alcohol. A
Teflon O-ring is hard, and must be expanded slightly (by hand)
before being mounted.
(8) Insert the new discharge tube into the discharge tube holder by
reversing step (4), then perform assembly by reversing steps (3)
and (5).
(9) Attach the cable or feeder between the matching box and
discharge tube. Note that the cable or feeder must not be placed
closely to other cables, feeders, and metal plates.
(10) After the replacement, start the oscillator, check for leakage, and
perform discharge aging.
If the discharge area of the new discharge tube greatly differs
from those of the other discharge tubes, adjust the power supply.