B-70265EN/02 9.LASER SOFTWARE FUNCTION
- 235 -
9.4.4 Bell-shaped Filter for Power Feedback Gain
To suppress output command value variation due to power feedback
at the time of output command value switching, a bell-shaped filter
can be applied to the power feedback gain.
(1) Filter setting method
Set PRM No. 29001 and PRM No. 29002.
29001 Time constant 1 (T1) for bell-shaped filter for power feedback gain
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
Set a time constant for a linear section. When 0 is set in this
parameter, the bell-shaped filter is not used.
29002 Time constant 2 (T2) for bell-shaped filter for power feedback gain
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
Set a time constant for a round section.
A bell-shaped filter can be specified by setting two time
constants: one for the linear section T1 (PRM No. 29001) and
the other for the round section T2 (PRM No. 29002).
T1
T2
t
Gain