3.INSTALLATION B-70265EN/02
- 36 -
3.2.2.3 Anticorrosive
Add the following anticorrosive to cooling water immediately after
installation to prevent problems due to corroding cooling water and to
decrease the frequency of replacement of cooling water.
Consult the chiller manufacturer for use of the anticorrosive.
Product name Manufacturer
1 CONTLIME K-6000 MITSUBISHI GAS CHEMICAL. Inc
2 Kurilex L-111 Kurita Water Industries LTD.
Use :
Add the anticorrosive to cooling water in concentration of 1000
to 2000 ppm (100 to 200 cc/100 liters). Monthly check the
concentration of the anticorrosive using concentration check
paper dedicated to anticorrosives and add the anticorrosive to
cooling water until the concentration reaches about 1000 ppm.
Concentration check paper :
Purchase a concentration check set (50 sheets of check paper, a
dropping pipette, etc.) together with CONTLIME K-6000
(manufactured by Mitsubishi Gas Chemical Inc).
CAUTION
If the above anticorrosive is added to cooling water
and the concentration is controlled, also be sure to
replace the cooling water every year.
3.2.2.4 Cleaning agent
To remove foreign matters such as fur that have adhered to the inside
of the cooling water circulating path, wash the cooling water
circulating path using the following detergent. Consult the chiller
manufacturer for use of the detergent.
Product name Manufacturer
1 DESLIME MITSUBISHI GAS CHEMICAL. Inc
2 Kuridine I-302 Kurita Water Industries LTD.
Use:
Add the detergent of 10% of the amount of cooling water,
circulate the water for an hour, then drain the water. After that,
rinse the cooling water circulating path thoroughly. Do not touch
a stock solution of DESLIME with your bare hands because the
solution is a strong chemical. If a stock solution accidentally
contacts your skin, wash the stock solution off your skin well
under running water.
If waste water used for washing is left standing, the main
ingredient, hydrogen peroxide, is decomposed. Wait until
hydrogen peroxide is decomposed, or dilute waste water with
water to reduce the concentration, then flush the waste water
down the drain.