E.PARAMTER LIST APPENDIX B-70265EN/02
- 278 -
FOV If the feedrate override is changed in the power control mode:
0: The new override after the change is used as the reference
feedrate for power control.
1: The reference feedrate for power control remains unchanged.
SDB Specifies how to specify an allowable variation in power control
speed (parameter No. 15095), as follows:
0: Speed (mm/min) to be directly specified
1: Percentage (0 to 100%) of the speed specified when the power
control mode was entered to be specified
EGM
0: Cancels the power control mode in the edge machining or start-
up processing mode.
1: Stops power control only during return distance movement in the
edge machining or start-up processing mode.
In the edge machining or start-up processing mode, the E number for
specifying conditions for edge machining or start-up processing is
selected.
15097
Parameter for calculating the displacement of the output
(output at a speed of F = 0)
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
15098
Parameter for calculating the displacement of the frequency
(frequency at a speed of F = 0)
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000
15099
Parameter for calculating the displacement of the duty ratio
(duty ratio at a speed of F = 0)
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100