#7
ALD201
#6 #5 #4
EXP
#3 #2 #1 #0
When OVL equal 1 in diagnostic data No.200 (servo alarm No. 400 is
being generated):
#7 (ALD) 0 : Motor overheating
1 : Amplifier overheating
When FBAL equal 1 in diagnostic data No.200 (servo alarm No. 416 is
being generated):
ALD EXP Alarm details
1 0 Built–in pulse coder disconnection (hardware)
1 1 Separately installed pulse coder disconnection
(hardware)
0 0 Pulse coder is not connected due to software.
#7
204
#6
OFS
#5
MCC
#4
LDA
#3
PMS
#2 #1 #0
#6 (OFS) : A current conversion error has occured in the digital servo.
#5 (MCC) : A magnetic contactor contact in the servo amplifier has welded.
#4 (LDA) : The LED indicates that serial pulse coder C is defective
#3 (PMS) : A feedback pulse error has occured because the feedback cable is
defective.
(7) Over travel alarms
Number Message Contents
500 OVER TRAVEL : +n Exceeded the n–th axis (axis 1–8) + side stored stroke check I.
(Parameter No.1320 or 1326 NOTE)
501 OVER TRAVEL : –n Exceeded the n–th axis (axis 1–8) – side stored stroke check I.
(Parameter No.1321 or 1327 NOTE)
502 OVER TRAVEL : +n Exceeded the n–th axis (axis 1–8) + side stored stroke check II.
(Parameter No.1322 )
503 OVER TRAVEL : –n Exceeded the n–th axis (axis 1–8) – side stored stroke check II.
(Parameter No.1323)
504 OVER TRAVEL : +n Exceeded the n–th axis (axis 1–8) + side stored stroke check III.
(Parameter No.1324 )
505 OVER TRAVEL : –n Exceeded the n–th axis (axis 1–8) – side stored stroke check III.
(Parameter No.1325 )
506 OVER TRAVEL : +n Exceeded the n–th axis (axis 1–8) + side hardware OT.
507 OVER TRAVEL : –n Exceeded the n–th axis (axis 1–8) – side hardware OT.
508 INTERFERENCE: +n
(T series (two–path control))
A tool moving in the positive direction along the n axis has fouled anoth-
er tool post.
509 INTERFERENCE: –n
(T series (two–path control))
A tool moving in the negative direction along the n axis has fouled anoth-
er tool post.
510 OVER TRAVEL: +n Alarm for stroke check prior to movement. The end point specified in a
block falls within the forbidden area defined with the stroke check in the
positive direction along the N axis. Correct the program.
511 OVER TRAVEL: –n Alarm for stroke check prior to movement. The end point specified in a
block falls within the forbidden area defined with the stroke check in the
negative direction along the N axis. Correct the program.
APPENDIXA. ALARM LIST
GFKE-0222-EN
868