FANUC Power Mate 0
Maintenance manual
TITLE
THE REFERENCE POINT ESTABLISHED FLAG
OF THE ABSOLUTE PULSE CODER
When the backup data is restored to Power Mate 0, the reference point
established flag of the absolute pulse coder(1815#4) is cleared. After restoring
operation, you need to establish a reference point of the absolute pulse coder
again. (Usually the restore operation is done when the master PCB of Power
Mate 0 is exchanged. Because the counter value of ABSOLUTE PULSE CODER
is lost at that time, the reference point established flag is cleared automatically.)
NOTE
・ Please be sure to use the flash memory card specified by FANUC when this
function is used. (For detail, please refer to the appendix D. "Treatment of a
memory card" in the Power Mate 0 maintenance manual.)
・ This function is effective at the moment the power supply is turned on. So set the
position of the rotary switch to 0 when this function is not used.
B-63445EN/01-2
4 / 4
EDIT
DATE DESIG. DESCRIPTION
DRAW.NO.
CUST.
SHEET
01
020118
New design