3. INPUT AND OUTPUT OF DATA
B–63445EN/01
78
1 Select EDIT (editing) mode.
2 Press function key
SYSTEM
.
3 Press the rightmost soft key
(next–menu key) and press chapter
selection soft key
[PITCH].
4 Press soft key [(OPRT)].
5 Press rightmost soft key
(next–menu key).
6 Press soft keys [PUNCH] and [EXEC].
All parameters are output in the defined format.
1 Select the EDIT (editing) mode.
2 Press the
key to display the pitch error compensation data screen.
3 Press the
key.
4 When necessary, perform a file head search.
1. Set to the emergency stop state.
2. Press
SYSTEM
key and soft key [PARAM] to display parameter screen.
3. Press soft key [(OPRT)] ,and soft key
.
4. Press soft key [READ] and [EXEC]. Then input of parameters are
started.
5. After the parameters have been input, turn off the power once then turn
it on because P/S alarm 000 is occured.
1. Set to the emergency stop state.
2. The parameter screen is selected by pressing the
key.
3. Set PWE on the setting screen to 1. Alarm PS100 is displayed at this
time.
4. Press
key.
5. NC parameters are input by this operation. Normally, alarm PS000
will activate after completion of parameter reading. Nomally, P/S
alarm 000 is generated after parameters have finished being read in.
6. Set PWE on the setting parameter to 0.
7. Turn on the Power Mate power again.
8. Perform zero point setting.
3.2.8
Outputting Pitch Error
Compensation Value
Procedure (CRT/MDI)
Procedure (DPL/MDI)
3.2.9
Inputting CNC
Parameters
D Procedure (CRT/MDI)
D Procedure (DPL/MDI)