1. DISPLAY AND OPERATION
B–63445EN/01
34
(4) Select the bit to be recorded.
To select all bits of the specified signal address, press the [ON:1] soft
key while the cursor is positioned to
00000000 .
To select a particular bit, position the cursor to that bit by pressing the
cursor key
or , then press the [ON:1] soft key. To cancel
a selection made by pressing the [ON:1] soft key or to cancel a
previously selected signal, press the [OFF:0] soft key.
(5) Up to 20 addresses can be specified by means of this signal selection.
These addresses need not always be specified at consecutive
positions, starting from No.1.
(6) Pressing the [ALLDEL] and [EXEC] soft keys deletes all data. If
the [ALLDEL] key is pressed by mistake, it can be cancelled by
pressing the [CAN] key.
(7) To delete a selected signal address, position the cursor to the
corresponding position then press the [DELETE] and [EXEC] soft
keys. In the SIGNAL column, asterisks ******** are displayed in
place of the deleted data. In the ADDRES column, the corresponding
position is cleared.
If the [DELET] key is pressed by mistake, it can be cancelled by
pressing the [CAN] key.
(8) Pressing the return menu key [
] causes the [OPEHIS] (operation
history) soft key to be displayed again.
NOTE
1 A cross (×) indicates that a signal will not be recorded. Also,
any signal for which an address is not specified will not be
recorded, either.
2 A circle (f) indicates that a signal can be recorded.
3 A signal indicated by its symbol name will also be displayed
by its symbol name.
D Input signals and output
signals to be recorded in