3. INPUT AND OUTPUT OF DATA
B–63445EN/01
76
1. Select EDIT mode.
2. Select the offset data display screen by pressing
key.
3. Press the
key.
4. While offset, is being output, the display appears as below.
0. 0 0 0
WRITE
T001X=
5. In order to stop output of data from a tape before it has finished, turn
on external reset signal ERS (bit 7 of G008).
Once data output from a tape has been stopped, it cannot be restarted.
1. Confirm the following parameters. If 1 is set, set to the MDI mode and
set it to 0.
#7 #6 #5 #4 #3 #2 #1 #0Address
3202 NE9 NE8
#4(NE9)l0 : Programs of 9000s are edited.
1 : Programs of 9000s can be protected.
#0(NE8)l0 : Programs of 8000s are edited.
1 : Programs of 8000s can be protected.
2. Select EDIT mode.
3. Press
key and press soft key [PRGRM] to display program text.
4. Press [(OPRT)] key and press soft key
.
5. Input a program number to be output. To output all programs input as:
O
–
9 9 9 9
6. Press [PUNCH] and [EXEC] key, then program output is started.
A program registered in memmory can be punched using the procedure
below.
1. Confirm parameter as like above 1.
2. Select EDIT (editing) mode.
3. Press
to display the program screen.
4. Key in address
.
5. Key in a desired program number.
Entering causes all programs in memory to
be output.
6. The number of input program is punched with pushing .
D Procedure (DPL/MDI)
3.2.6
Outputting Part
Program
D Procedure (CRT/MDI)
D Procedure (DPL/MDI)