6.DATA SERVER FUNCTIONS FOR THE 15i III. SETTING B-63644EN/02
- 98 -
5031 Wait time for FOCAS1/Ethernet
[Data type] Word
[Valid data range] 1.1ms
[Valid data range] 0 to 32767
Specifies the wait time in 1.1 ms for each service of the
FOCAS1/Ethernet when it is used together with the data server
function.
If a value 0 is specified, a wait time of 1.1 ms is assumed.
#7 #6 #5 #4 #3 #2 #1 #0
5038 LCK BWT
[Input section] Parameter input
[Data type] Bit
LCK Specifies whether to check if there is a duplicate file name
specification in a list file when the LIST-GET data server function is
used, as follows:
1: To check.
0: Not to check.
BWT Specifies whether to detect an error if the FTP communication is not
finished in time when the DNC operation is in the data server function
buffer mode, as follows:
1: Not to detect an error; the DNC operation is continued after the
FTP communication is finished.
0: To detect an error.
#7 #6 #5 #4 #3 #2 #1 #0
5039 DNCE
[Data type] Bit
DNCE In DNC operation of FOCAS1/Ethernet, the end of DNC operation is:
0: Awaited.
1: Not awaited. (Compatible with HSSB)
NOTE
Be sure to set this bit to 0 when using
DNC1/Ethernet.
#7 #6 #5 #4 #3 #2 #1 #0
5040 DSW
[Input section] Parameter input
[Data type] Bit
DSW Specifies the output if an error occurs during a data server operation
(except reading and punching operations).
1: Warning
0: BG alarm