bout the error messages
B-63644EN/02-6
B.5 FAST_ETH FOCAS1 #0, #1, #2 LOG Screen
FAST_ETH CNC SCREEN #1, #2 LOG Screen
FAST_ETH PMC LOG Screen
TCP PORT NUMBER(%d) IS INVALID
The setting(%d) of the TCP port number for FOCAS1/Ethernet is
incorrect. Correct the TCP port number.
ALL TASKS(C%d) ARE BUSY
The FOCAS1/Ethernet function is already engaged in communication
with five applications. Terminate the communication with unnecessary
applications on the personal computer.
CONNECTION RESET BY PEER
The connection was reset by the personal computer.
Sometimes an electrical noise causes resetting the connection.
CONNECTION ESTABLISH HAS NOT STARTED
The connection is already closed.
Sometimes an electrical noise causes resetting the connection.
CONNECTION IS SHUTDOWN
The connection was reset by the personal computer.
Sometimes an electrical noise causes resetting the connection.
Err EthInitiateDownload() [%d]
An error occurred when starting download data. The error code is [%d].
Err EthAbortDownload() [%d]
An error occurred when aborting download data. The error code is [%d].
Err EthDownloadSegment() [%d]
An error occurred when receiving download data. The error code is [%d].
Err EthTerminateDownload() [%d]
An error occurred when terminating download data. The error code is
[%d].
Err EthInitiateDnc() [%d]
An error occurred when starting DNC operation. The error code is [%d].
Err EthAbortDnc() [%d]
An error occurred when aborting DNC operation. The error code is [%d].
Err EthDncSegment() [%d]
An error occurred when receiving data for DNC operation. The error
code is [%d].