8/21
TITLE
Addition of Machine Remote Diagnosis
and Unsolicited Message
Explanation of RMT DIAG STATUS
Status Meaning
-- -- -- Idle, Machine Remote Diagnosis is not being used.
OPEN Soft key [OPEN] is just pressed.
OPENING
CNC is connecting to the package of PC.
ACCEPTED
The package accepted the request of Machine Remote Diagnosis
from this CNC.
REFUSED
The package refused the request of Machine Remote Diagnosis
from this CNC.
DIAGNOSING
The package is diagnosing this CNC.
The status blinks, conforming to the actual communication flow.
CLOSE The package completed the diagnosis of CNC.
FORCE
CLOSING
Soft key [CLOSE] is just pressed.
The status is changed to “__ __ __” automatically, after finishing
the closing process.
ERROR An error occurred during the communication.
SHEETDESCRIPTIONDESIGN DATE EDIT
01
02.06.21
Mutai First issue
B-63644EN/02-3
FANUC LTD.
DRAW.NO.