B-63644EN/02 III. SETTING 4.DATA SERVER FUNCTIONS FOR THE 16i/18i/21i
- 73 -
4.3 PARAMETERS
The following describes the parameters related to the data server
functions.
Parameters
0020 I/O CHANNEL: Selects an I/O device.
[Data type] Byte
[Valid data range] 0 to 35
5: Selects the data server for the I/O device.
#7 #6 #5 #4 #3 #2 #1 #0
900 LCK BWT
[Data type] Bit
DSV The data server function is
1: Disabled
0: Enabled
ONS When the O number of the data server file name and the O number in an
NC program do not match:
1: The O number in the NC program takes priority.
0: The O number of the file name takes priority.
#7 #6 #5 #4 #3 #2 #1 #0
904 LCK BWT
[Data type] Bit
LCK Specifies whether to check if there is a duplicate file name
specification in a list file when the LIST-GET data server function is
used, as follows:
1: To check.
0: Not to check.
BWT Specifies whether to detect an error if the FTP communication is not
finished in time when the DNC operation is in the data server function
buffer mode, as follows:
1: Not to detect an error; the DNC operation is continued after the
FTP communication is finished.
0: To detect an error.
921 Selects the host computer OS.
[Data type] Byte
[Valid data range] 0 and 1
1: UNIX/VMS.
0: Windows 95/98/Me/NT/2000.
922 Selects the host computer 2 OS.
[Data type] Byte
[Valid data range] 0 and 1
1: UNIX/VMS.
0: Windows 95/98/Me/NT/2000.