Sheet
Title
Draw
No.
Ed. Date Design Description
Date Oct.29.2004 Desig. Apprv.
8/19
FAST Ethernet Board / FAST DATA SERVER
OPERATOR’S MANUAL
bout the error messages
B-63644EN/02-6
B.4 FAST_ETH FACTOLINK LOG Screen
FACTOLINK#%d IP ADDRESS(%s) IS INVALID
The setting(%s) of the IP address for FACTOLINK server is incorrect.
Correct the IP address.
FACTOLINK#%d PORT NUMBER(%d) IS INVALID
The setting(%d) of the TCP port number for FACTOLINK server is
incorrect. Correct the TCP port number.
FACTOLINK#%d IS TERMINATED.
Because the settings of FACTOLINK server are wrong, FACTOLINK
task is terminated. Correct the settings of FACTOLINK server.
FACTOLINK SERVER ISN'T ALIVE
The FACTOLINK server cannot be found on the network. Check if the
FACTOLINK server is connected to the network correctly.
ROUTER IP ADDRESS(%s) IS INVALID
The setting(%s) of the IP address of the router is incorrect. Correct the
IP address of the router.
ROUTER ISN'T ALIVE
The router cannot be found on the network. Check if the router is
connected to the network correctly.
Ping Service Error [%d]
An error[%d] occurred when the PING command was sent to the
FACTOLINK server.
NOT CONNECTED
A disconnection request or data send request was issued to a
non-connected port. Connect to the FACTOLINK server again.
ALREADY CONNECTED
Connection request was issued again to the already connected port.
FAIL TO CONNECT SOCKET
Failed to connect to the FACTOLINK server.
Check the FACTOLINK server is activated normally.