B-63644EN/02 APPENDIX B.TROUBLES & ERROR MESSAGES
- 371 -
B.2 DNC1/Ethernet OR FOCAS1/Ethernet FUNCTION
PARAMETER LOG screen
OWN IP ADDRESS(???) IS INVALID The set value (???) of the own IP address is in error. Set the own IP
address to the correct value.
SUBNET MASK(???) IS INVALID The set value (???) of the subnet mask is in error. Set the subnet
mask to the correct value.
ROUTER IP ADDRESS(???) IS INVALID The set value (???) of the router IP address is in error. Set the
router IP address to the correct value.
TCP PORT NUMBER(???) IS INVALID The set value (???) of the TCP port No. by the DNC1/Ethernet or
FOCAS1/Ethernet function is in error. Set the TCP port No. to the
correct value.
UDP PORT NUMBER(???) IS INVALID The value (???) of the UDP port No. set with the DNC1/Ethernet
function is incorrect. Set a correct UDP port No..
UDP INTERVAL TIME (???) IS INVALID The value (???) of the UDP packet transmission interval set with
the DNC1/Ethernet function is incorrect. Set a correct UDP packet
transmission interval.
Err boot_mmc(): ??? An attempt to initialize the DNC1/Ethernet function or
FOCA1/Ethernet function failed. Replace the system with a CNC
system or PMC system that supports the DNC1/Ethernet function
or FOCA1/Ethernet function.
FOCAS1 #0 LOG screen
ALL TASKS(Cxx) ARE BUSY All tasks have been activated.
The number of sockets that are connectable with the
DNC1/Ethernet function or FOCA1/Ethernet function was
exceeded. Terminate unnecessary applications, then reexecute the
service.